<<  Heizungssysteme

Heissluftgebläse

Hot Air Blower

Heissluftgebläse: wir liefern 2 Typen direkt und indirect betriebene Geräte, für Gas und Öl.



During the first days of the life of your birds, warmth is one of the most important management parts. The proper housing temperature right from the first day has a decisive influence on the future developments of the birds, and also on their growth, health and performance.

The hot-air blowers are used where a large amount of warmth is required throughout the entire house for a short period of time.
Two types of hot-air blowers are available to meet the different needs of poultry growers.

Star direct fired air heater
The Star direct fired air heaters are made of highgrade stainless steel, making them impervious to any unfriendly environment. The burner chamber comes in heat-resistant steel. The design of this ventilator burner guarantees excellent performance, this contributing towards an optimum indoor atmosphere at minimum heating costs. The automatic burner and ignition and photocell flame control unit guarantee a completely safe operation. The heaters always have an output of 100%.
The automatic burner control is mounted in a waterproof plastic casing. A fully automatic operation is achieved by means of a thermostat or computer.
The hot-air blowers are simpel to install, operate, maintain and control, and guarantee a constant and effective house temperature.

There are two types of hot-air blowers:

  • The GP-type: works with NOx (natural gas or propane) and comes in two sizes. For technical specification see table.
  • The P-type: works with oil (kerosine 28 sec. (Redwood) or gasoil 35 sec. (Redwood)), and comes in different sizes. For technical specifica- tion see table.




  • Capacity
    Air-displacement
    Fuel cons.
    Engine Power
    Weight
    Type
    kW
    BTUH
    m3/h
    CFM
    l/h
    kW
    kg
    P40
    40
    136000
    6200
    3600
    4
    0.3
    48
    P60
    60
    205000
    6200
    3600
    6
    0.3
    51
    P80
    80
    273000
    7700
    4500
    8
    0.44
    55
    P100
    100
    341000
    7700
    4500
    10
    0.44
    55
    P120
    120
    409000
    7700
    4500
    12
    0.44
    65
    All types: Mains 230V or 230/400 V50/60 Hz


    Capa-
    city
    kW
    Gas consumption
    Connecting Pressure
    Burner Pressure
    natural gas
    m3/h
    pro-
    pane
    kg/h
    natural gas
    mbar
    pro-
    pane
    mbar
    natural gas
    mbar
    pro-
    pane
    mbar
    GP40
    40
    4.3
    3.1
    25
    50
    12.5
    47
    GP70
    70
    7.5
    5.4
    25
    50
    13.5
    46
    GP95
    95
    9.8
    6.8
    20
    50
    12.5
    46
    GP120
    120
    12.5
    8.5
    20
    50
    13.5
    46

    Gas con-
    nection
    Electr. Power
    V/W
    Air current safety
    Gas pres-
    sure safety
    Flame safety
    Eff. heat range
    m
    Air-
    dis-
    place-
    ment
    m3/h
    Weights
    kg
    GP40
    Rp3/4''
    230/460
    switch
    switch
    ionisation
    40
    3900
    36
    GP70
    Rp3/4''
    230/650
    switch
    switch
    ionisation
    50
    5000
    36
    GP95
    Rp3/4''
    230/680
    switch
    switch
    ionisation
    40
    6500
    48
    GP120
    Rp3/4''
    230/700
    switch
    switch
    ionisation
    50
    7500
    64


    Star indirect fired air heater
    Specification:
    The fuel and the air stream are totally separated. The exhaust gases do not go into the building as they are exhausted out through the flues.
    The combustion chamber has an exclusive cylindrical design which works by flame inversion to reach high combustion temperature.

    The self cleaning design of the combustion chamber gives high CO2 levels and no scat. The chamber walls retain clear giving lower maintenance requirements and clean combustion equals high combustion efficiency.

    The heaters are supplied complete with electronic thermostat, two meters stainless steel flue and cap and roof plate.

    The thermostat controls the fan motor either manually or automatically and will switch off the burner in case of over heating.
    Heaters are either light oil (diesel) or gas (propane, LPG, methane) fired.

    The burner is fixed to an insulated plate; a spy hole in pyroglass to check combustion is included.
    An inspection plug, installed on the fan heater side, gives direct access to the combustion chamber and heater heat exchanger.
    The heater housing is made of pre-coated galvanised pluvimag steel for protection against corrosion.

    Technical Specification

    Model
    Thermal output
    Air heater (dimensions mm)
    Kcal/h
    KW
    A
    B
    Ø C
    Ø D
    GP30
    30,000
    35
    1370
    780
    400
    150
    GP50
    50,000
    58
    1570
    780
    400
    150
    GP80
    80,000
    93
    1760
    870
    500
    150
    GP100
    100,000
    116
    1890
    870
    500
    200
    GP130
    130,000
    150
    2000
    970
    600
    200

    Model
    Weight
    Burner
    Propeller
    Packing (dimensions mm)
    Kg
    W
    Gasoil (max Kg/h)
    KW
    MC/h
    Length
    Width
    Height
    GP30
    80
    90
    3.1
    0.25
    4300
    1600
    800
    930
    GP50
    100
    117
    5.6
    0.48
    5800
    1600
    800
    930
    GP80
    130
    117
    8.3
    1.03
    8500
    1930
    900
    1060
    GP100
    160
    117
    10.4
    1.32
    11000
    1930
    900
    1060
    GP130
    185
    185
    12.5
    1.32
    11000
    2030
    1000
    1150


    <<  Heizungssysteme

    September 2003
    STAR AGRI PRODUCTS B.V.
    P.O. Box 112, 6600 AC Wijchen, The Netherlands
    tel.: +31(0)24 - 6487222 fax: +31(0)24 - 6487223
    e-mail: star.agri@wxs.nl